An improved ZCAP auditory model with adaptability is proposed in this paper, and the  adaptive method designed for ZCPA model is suitable for other auditory model with inner-hair-cell sub-model. The first step in the implement process of the proposed ZCPA model is to carry out the calculation of inner product between signal and complex Gammatone filters to obtain important frequency components  of signal. And then, according to  the result of the first step, the parameters of the basilar membrane sub-model and frequency box are automatically adjusted, such as the number of the basilar membrane filters, center frequency and bandwith of each basilar membrane filter, position of each frequency box, and so on. Lastly  an auditory model is built, and the final output is auditory spectrum.The results of numerical simulation and experiments have showed that the proposed model could realize accurate frequency selection, and the auditory spectrum is more distinctly than that of conventional ZCPA model. Moreover, the proposed model can completely avoided the influence of the number of filter on the shape of auditory spectrum existing in conventional ZCPA model so that the shape of auditory spectrum is steady, and the data quantity is small.

 